CTC – GSI 616 – 400v GSHP – 589300003

GSI 616 16kw Ground Source Heat Pump R407c – Three Phase – Inverter Driven – Built in Control

SKU: 7333077094287 Category:

Description

CTC GSi adapts automatically to the building’s output requirements during the year. When high output is required, the output increases. When less output is required, the compressor shifts to lower output. This means that you will always achieve maximum savings.

CTC GSi is equipped with a highly efficient water heater, which produces over 300 litres of hot water. CTC GSi is ideal for family homes as well as larger properties. CTC GSi comes in 3 sizes, which enables it to be utilised in most properties. CTC GSi 608 with an output range at 2.5-7.7 kW, CTC GSi 612 at 2.5-12 kW and CTC GSi 616 at 4-16 kW.

CTC GSi has a seasonal coefficient of performance (SCOP) of 5.5, which means that, over the course of year, it produces 5 times as much energy as it consumes. Compressor and cooling components are enclosed in a separate, sound-insulated unit, which makes it very quiet – only 36 dB(A) at 50 rps. Furthermore, the entire heat pump has very efficient insulation, which minimises energy losses. CTC GSi is so energy efficient that it easily meets the requirements for an A+++ rating – the highest and best energy rating a heat pump can be given.

CTC GSi has a stylish white design and flexible modular dimensions that allow it to fit into most environments. Owing to the heat pump’s modular construction, it can be easily separated into two individual units. The brine system can be connected to the right, left or rear. All for simple and easy installation. The 4.3-inch colour touchscreen has clear symbols with English text, which makes it easy to adjust the heat and hot water or to retrieve a range of information about the operation.

The built-in automatic control is climate controlled and takes into account both indoor and outdoor temperatures. CTC GSi is able to control two individual heating systems as standard.

All CTC heat pumps and boilers are designed, developed and manufactured in our factory in Ljungby. This gives us total control of all stages of the production process – from manufacture up to delivery of the finished product.

All CTC heat pumps and boilers are designed, developed and manufactured in our factory in Ljungby. This gives us total control of all stages of the production process – from manufacture up to delivery of the finished product.

Variation

Technical Information

Three phase (400V) GSi 608 GSi 612 GSi 616
CTC no. 587303001 587304001 587307001
Weight (packaged weight) kg 309 (279) 265 (295) 275 (300)
Dimensions (H x W x D) mm 1910 x 596 x 673
Required ceiling height mm 1940
Electrical Data, connection 400V 3N~ 50Hz
Energy efficiency class in heating system @ 35/55°C (A+++ to G) A+++ / A+++
Energy efficiency class heat pump @ 35/55°C (A+++ to D) A+++ / A+++
Energy efficiency class DHW / charge profile (EN16147) (A+ to F) A / XL
DHW-performance (V40) Volume 40°C @ Economy/Normal/Comfort (EN16147) litres 210 / 235 / 304
Rated current (recommended fuse) A 13.3 (16) 24.9 (25) 23.8 (25)
Max. immersion heater output @ group fuse 10/13/16/20/25 A kW 2.1 / 2.1 / 2.9 / 5.8 / 5.8 0.3 / 0.9 / 2.1 / 7.2 / 9 – / 0.3 / 0.9 / 2.1 / 9*
Output range (specified output cooling module) kW 2.5 / 7.7 2.5 / 11.8 2016-04-01 00:00:00
Output range immersion heater kW 0.3 – 5.8 0.3 – 9 0.3 – 9
Ingress protection class (IP) IP X1
Specified output @ 5/35 | 5/45 | 5/55 @ 50 rps (EN14511) kW 7.1 / 6.65 / 6.36 7.1 / 6.65 / 6.36 12.26 / 11.22 / 10.55
COP @ 5/35 | 5/45 | 5/55 @ 50 rps (EN14511) 5.62 / 4.26 / 3.57 5.62 / 4.26 / 3.57 5.07 / 3.87 / 3.14
Specified output @ 0/35 | 0/45 | 0/55 @ 50 rps (EN14511) kW 6.08 / 5.68 / 5.24 6.08 / 5.68 / 5.24 10.52 / 9.58 / 8.90
COP @ 0/35 | 0/45 | 0/55 @ 50 rps (EN14511) 4.78 / 3.68 / 2.95 4.78 / 3.68 / 2.95 4.50 / 3.43 / 2.72
SCOP (Pdesignh) cold climate @ 0/35 | 0/55 (EN14825) 5.6 / 4.2 5.5 / 4.3 5.5 / 4.2
SCOP (Pdesignh) moderate climate @ 0/35 | 0/55 (EN14825) 5.4 / 4.2 5.4 / 4.1 5.2 / 4.0
Water volume – Heating system (V) litres 229
Water volume – Water supply system (V) litres 1.7
Refrigerant quantity (R407C, fluorinated greenhouse gas GWP 1774) kg 2.4 2.4 2.2
CO2 equivalent tonnes 4.258 4.258 3.903
Sound power @ 0/35 | 0/55 (according to EN12102) dB(A) 39 / 41 39 / 41 36 / 40